R&S®TS-PFG Function Generator Module
В продаже Модульные приборы R&S®TS-PFG Function Generator Module оптом и в розницу. Нашли дешевле? Предоставьте свою цену, Мы сформируем более выгодное предложение. При заказе от 3000р., доставка по Самаре - БЕСПЛАТНО! Возможна отправка товара в любую точку РФ транспортной компанией.
Цена:
Технические характеристики
Характеристики - R&S®TS-PFG Function Generator Module
Dual-channel arbitrary waveform generator with isolated outputsKey Facts
- Floating signal output with independent channel isolation
- Wide dynamic range with 16-bit resolution
- High sampling rate of 25 Msample/s per channel
- 1 MHz sine, square, triangle, arbitrary standard waveforms
- High output level range from ±1 V to ±20 V, 40 Vpp
- High output current of max. ±250 mA
- 1 Msample memory depth per channel
- Dynamic reconfiguration of amplitude during waveform output
- Sequencing of multiple memory sections and multiple repetitions
- Selftest capabilities
- Analog measurement bus access to eight bus lines
- Soft front panel support for immediate deployment
- LabWindows/CVI device driver support
- GTSL test software library in DLL format
Brief Description The R&S®TS-PFG function generator module is a CompactPCI/PXI module which takes up only one slot in the R&S®CompactTSVP test system versatile platform.
Specifications
| Application in the R&S®TSVP platform | R&S®CompactTSVP | 1 slot required | |
| Interface | |||
| Control bus | CompactPCI/PXI | ||
| DUT connector (front) | DIN 41612, 96 pins | ||
| Rear I/O connector | CompactPCI, 110 pins | ||
| Signal generation | |||
| Output resolution | 16 bit | ||
| Number of analog channels | fully independent or synchronous, differential, floating, cascadable, short-circuit-proof | 2 | |
| Digital marker channels | one per channel | 2 TTL | |
| Memory (RAM) | 1 Msample per channel | ||
| Signal output modes | |||
| DC mode | static value | ||
| Sinewave | 1 Hz to 1 MHz (max.) | ||
| Triangle, ramp | 1 Hz to 1 MHz (max.) | ||
| Squarewave | 1 Hz to 1 MHz (max.) | ||
| Pulse (high – low) | 1 % to 99 % (min. pulse width 500 ns) | ||
| Arbitrary waveforms in burst mode | sample rate | DC, 1 sample/s to 25 Msample/s | |
| waveform length | 1 to 1048576 (1 M) points per channel if sample rate = 25 Msample/s: 18 to 1048576 (1 M) points per channel | ||
| resolution | 40 ns (min.) | ||
| chaining of sequences | 256 per channel, max. 16 382 cycles per segment | ||
| Timing control | |||
| Continuous mode | frequency | 1Hz to1 MHz | |
| resolution | 0.004 % of setting | ||
| accuracy | ±(resolution + reference clock accuracy) | ||
| Reference clock | PXI clock of R&S®TS-PCA3, 10 MHz, ±(1.5 ppm + 1 ppm/year) | ||
| Output voltage | amplitude range | ||
| Output mode | output voltage (max.) | ||
| Single channel, GND referenced | ±20 V, ±10 V, ±5 V, ±1 V | ||
| Single channel, floating | ±20 V, ±10 V, ±5 V, ±1 V | ||
| Cascaded channels | ±40 V, ±20 V, ±10 V, ±2 V | ||
| Output current | max. load current, depending on frequency | ||
| Output mode | f ? 300 kHz | 300 kHz ? f ? 500 kHz | 500 kHz ? f ? 1 MHz |
| Single channel, GND referenced | 250 mA | 250 mA | 125 mA |
| 250 mA | 250 mA | 125 mA | |
| 250 mA | 125 mA | 50 mA | |
| Amplitude accuracy (no load) | 1 Hz to 100 kHz | 100 kHz to 1 MHz | |
| Range | Resolution | Error limits | Error limits |
| 20 V | 0.6 mV | ±0.25 dB | ±0.5 dB |
| 10 V | 0.3 mV | ±0.25 dB | ±0.5 dB |
| 5 V | 0.15 mV | ±0.3 dB | ±0.5 dB |
| 1 V | 0.03 mV | ±0.3 dB | ±0.5 dB |
| Temperature coefficient for amplitude | 0 % to –0.05 %/°C of range | ||
| Offset range | –20 V to +20 V (offset + amplitude less than amplitude range limits) | ||
| Offset resolution | 12 bit | ||
| DC offset accuracy (no load) | |||
| Range | Resolution | Error limits | |
| ±20 V | 10 mV | ±(0.5 % + 100 mV) | |
| ±10 V | 2 mV | ±(0.5 % + 80 mV) | |
| ±1 V | 0.5 mV | ±(0.5 % + 20 mV) | |
| Temperature coefficient DC offset | 0 % to –0.04 %/°C of range | ||
| Source impedance | < 2.5 ?, 1.25 ? (typ.) | ||
| Output coupling | DC | ||
| Bandwidth with lowpass filter (3 dB) | 3 MHz/100 kHz/3 kHz (programmable for arbitrary mode) | ||
| Crosstalk (typ.) | –70 dB at 100 kHz, –60 dB at 1 MHz | ||
| Spectral purity (sinewave) | |||
| Harmonic distortion, frequency range 20 Hz ? f ? 50 kHz | |||
| Output Vpp | Harmonic distortion (typ.) | ||
| ? 200 mV | < –70 dBc | ||
| ? 2 V | < –65 dBc | ||
| ? 20 V | < –48 dBc | ||
| ? 40 V | < –40 dBc | ||
| Synchronization, per channel | |||
| Trigger inputs | 1 ? local trigger (TTL), 8 ? PXI trigger bus | ||
| Slope | positive/negative | ||
| Pattern | 9 bit, 3 states: high, low, don’t care | ||
| Delay | 40 ns to 100 s | ||
| Trigger outputs | 1 ? local trigger (TTL), programmable marker synchronous with analog signal, 8 ? PXI trigger bus, marker channels may be used as separate digital channels | ||
| Analog measurement bus and relay multiplexer | |||
| R&S®CompactTSVP analog measurement bus | 8 lines | ||
| Relay scanner (per channel) | two pole ? 8-to-1 multiplexer to local analog bus | ||
| Coupling relays | 8, local bus to global analog bus | ||
| Switching voltage | 125 V DC/90 V RMS (max.) | ||
| Switching current | 1.0 A (max.) | ||
| Switching power DC/RMS | 10 W/10 VA (max.) | ||
| Isolation (channel-to-channel, channel-to-earth) | 125 V | ||
| General data | |||
| Power consumption | +5 V/3.0 A (typ.) | ||
| ? 8.5 A (max.) | |||
| +3.3 V/1.3 A | |||
| incl. R&S®TS-PDC | 47 W (max.) | ||
| Environmental conditions | |||
| Temperature | operating temperature range | +5 °C to +40 °C | |
| storage temperature range | –10 °C to +60 °C | ||
| Damp heat | +40 °C, 80 % rel. humidity, steady state, in line with EN 60068-2-30 | ||
| Mechanical resistance | |||
| Vibration | sinusoidal | 5 Hz to 55 Hz, 0.15 mm amplitude const., 55 Hz to 150 Hz, 0.5 g const., in line with EN 60068-2-6 | |
| random | 10 Hz to 300 Hz, acceleration 1.2 g (RMS), in line with EN 60068-2-64 | ||
| Shock | 40 g shock spectrum, in line with MIL-STD-810E, method 516.4, procedure I | ||
| Product conformity | |||
| Electromagnetic compatibility | EU: in line with EMC Directive 2004/108/EC | applied harmonized standards: EN 61326-1 (industrial environment), EN 61326-2-1, EN 55011 (class A), EN 61000-3-2, EN 61000-3-3 | |
| Electrical safety | EU: in line with Low Voltage Directive 2006/95/EC | applied harmonized standard: EN 61010-1 | |
| Dimensions | W ? H ? D | 20 mm ? 174 mm ? 316 mm (0.79 in ? 6.85 in ? 12.44 in) | |
| Weight | 0.5 kg (1.1 lb) | ||
| incl. R&S®TS-PDC | 0.8 kg (1.76 lb) | ||
| Recommended calibration interval | 12 months |