Measurement of disturbance power and screening effectiveness on cablesKey Facts
- Frequency range from 30 MHz to 1000 MHz
- Maximum cable diameter: 20 mm
- Clamp opens for easy insertion of the test cable
- Ball bearing rollers for continuous use in automatic measurements
- Requirements and calibration in line with CISPR 16-1-3
Brief Description The R&S®MDS-21 absorbing clamp meets the requirements of CISPR 16-1-3/EN 55016-1-3 for disturbance power measurements in the frequency range of 30 MHz to 1000 MHz and is applicable for screening effectiveness measurements. The disturbance emitted by electrical appliances, machines and systems must comply with the limits specified in national and international standards. MDS absorbing clamps (Meyer de Stadelhofen) in conjunction with EMI measuring receivers are used to measure the disturbance power on cables in line with CISPR 13/EN 55013, CISPR 14-1/EN 55014-1 and EN 50083-2. They can also be used in conjunction with two-port measuring devices to measure the screening effectiveness of cables in line with IEC 62153-4 and EN 50083-2. MDS absorbing clamps are also used to test the efficiency of disturbance suppression devices for high-voltage ignition systems in line with CISPR 12/EN 55012. In the frequency range below 30 MHz, the interference stipulated in many standards is defined by measuring the disturbance voltage produced by the EUT at the terminals of a line-impedance stabilization network. This is important because disturbance in this frequency range is mainly propagated via cables. Above 30 MHz, where radiated disturbance is predominant, the interference is defined by the disturbance field strength at a certain distance. Small EUTs mainly emit disturbance via connected cables, e.g. power cables. For this reason, and also to reduce extensive field strength measurements to a minimum, many standards stipulate the MDS absorbing clamp to measure the disturbance power.
Specifications
| R&S®MDS-21 specifications | ||
| Frequency range | 30 MHz to 1000 MHz | |
| Insertion loss | in line with CISPR 16-1-3 | 17 dB ±4 dB (nom.) |
| Decoupling factor DF | in line with CISPR 16-1-3 | > 21 dB |
| Decoupling factor DR | in line with CISPR 16-1-3 | > 30 dB |
| Receiver input impedance | 50 ? | |
| Maximum permissible DC current or peak value of AC current | 30 A | |
| Maximum permissible RF input power | immunity measurements | 5 W |
| Maximum cable diameter | 20 mm | |
| Maximum cable diameter | with spacer | 6 mm |
| Connectors | ||
| RF output/input | disturbance power/immunity measurements | N female, 50 ? |
| General data | ||
| Operating temperature range | +5 °C to +45 °C | |
| Storage temperature range | –40 °C to +70 °C | |
| Dimensions, overall | W ? H ? D | 625 mm ? 106 mm ? 106 mm (24.6 in ? 4.2 in ? 4.2 in) |
| Weight | 6.9 kg (15.2 lb) |