Измерительная система Keyence IM-6700

В продаже Измерительные системы Измерительная система Keyence IM-6700 оптом и в розницу. Нашли дешевле? Предоставьте свою цену, Мы сформируем более выгодное предложение. При заказе от 3000р., доставка по Самаре - БЕСПЛАТНО! Возможна отправка товара в любую точку РФ транспортной компанией.

КУПИТЬ В 1 КЛИК
Цена:
Измерительная система Keyence IM-6700

Технические характеристики

Характеристики - Измерительная система Keyence IM-6700

Controller
ModelIM-6700
TypeController
Image sensor1' 6.6 mega pixel monochrome CMOS
Display10. 4' LCD monitor (XGA: 1024 ? 768) External monitor connectable (clone output)
Receiver lensDouble telecentric lens
Image measurementField of viewWide field: o100 ? L200 mm, High precision: 25 ? L125 mm
Minimum display unit0.1 µm
RepeatabilityW/o stage movementWide field: ±1 µm, High precision: ±0. 5 µm
With stage movementWide field: ±2 µm, High precision: ±1. 5 µm
Measurement accuracy (±2?)W/o bindingWide field: ±5 µm*1, High precision: ±2 µm*2
With bindingWide field: ±(7 + 0. 02 L) µm*3, High precision: ±(4 + 0. 02 L) µm*4
External remote inputNon-voltage input (with and without contact)
External outputOK/NG/FAIL/MEAS.Relay output/rated load: 24 VDC, 0. 5 A/ON resistance
InterfaceLANRJ-45 (10BASE-T/100BASE-TX/1000BASE-T)
USB 2.0 series A6 ports (front: 2, rear: 4)
RecordHard disk drive250 GB
Illumination systemTransparentTelecentric transparent illumination
RingFour division, multi-angle illumination (electric) Slit ring (directivity) illumination (electric)
X stageMoving range100 mm (electric)
Z stage30 mm (electric)
Withstand load2 kg
Measurement points99 points max. (99 ? 9 points possible when the function for consolidating measurement settings is used)
Pattern search (profi le tracking function)XY? (with 360° rotary position compensation)
Pattern registration1000 patterns or more*5
Measurement time2 seconds*6
Basic measurement functionDistance measurement8 types (point-point/line-point/line-line/circle-point/circle-line/circle-circle/circle/arc)
Angle measurementProvided
Calculation
Virtual line functionPointMiddle point/intersection
Conjunction edgeLine conjunction/circular conjunction
Line6 types (midline/perpendicular line/parallel lines/tangent line/line passing through a point/approximate line)
CircleMiddle circle/approximate circle/auxiliary circle/inscribed and circumscribed circle
Application toolPitch measurementLine/circumference
Pitch angle
Width measurementEdge width
Thickness measurementThickness measurement/gap measurement between inner and outer diameters
Special toolRounded corner/curved surface/oval/reticle/point position/perimeter/area/screw/automatic measurement
GD&TShape toleranceStraightness/circularity/profile
Orientation toleranceSquareness/parallelism
Position tolerancePoint position/concentricity
Element toolPointPoint (on a line or arc)/maximum and minimum (rectangle, circle, arc)
LineLine/centre line/peak line
CircleCircle/arc/peak circle/peak arc
Profi le extractionProvided
Special toolAutomatic generation/gauge line
Manual measurementProvided
Coordinate system confi guration
Batch confi guration of tolerance
Element list editing
Measurement setting data binding function
DXF export function
Automatic measurement function
Q-DAS data save function
Measurement settings support functionsProvided*7
Power supplyPower voltage100 to 240 VAC 50/60 Hz
Power consumption310 VA max.
Environmental resistanceAmbient temperature+10 to +35 °C
Relative humidity20 to 80 % RH (No condensation)
WeightApprox. 8 kg
*1 In the range of o80 mm from the centre of the stage within the operating ambient temperature range of +23°C ±1.0°C at the focused focal point position *2 In the range of o20 mm from the centre of the stage within the operating ambient temperature range of +23°C ±1.0°C at the focused focal point position *3 In the range of o80 ? 180 mm from the centre of the stage, within the operating ambient temperature range of +23°C ±1.0°C at the focused focal point position, and with a load weighing 1 kg or less on the stage (L = amount of stage movement in mm units) *4 In the range of o20 ? 120 mm from the centre of the stage, within the operating ambient temperature range of +23°C ±1.0°C at the focused focal point position, and with a load weighing 1 kg or less on the stage (L = amount of stage movement in mm units) *5 Depending on the measurement setting data and number of data pieces being stored *6 Without pattern search, applied measurement, and stage movement *7 Optimum lighting guide, optimum lighting search, automatic edge extraction parameter adjustment function, and multiple edge extraction function