Measurement Head: Wide-field model
ModelIM-6125
TypeMeasurement head
Image sensor1' 6.6 mega pixel CMOS
Display10.4' LCD monitor (XGA: 1024 ? 768) External monitor connectable (clone output)
Receiver lensDouble telecentric lens
Image measurementField of viewWide field: o100 ? L200 mm, High precision: 25 ? L125 mm
Minimum display unit0.1 µm
RepeatabilityW/o stage movementWide field: ±1µm High precision: ±0.5µm
With stage movementWide field: ±2µm High precision: ±1.5µm
Measurement accuracy (±2?)W/o bindingWide field: ±5µm*1 High precision: ±2µm*2
With bindingWide field: ± (7 +0.02L)µm*3 High precision: ± (4 +0.02L)µm*4
External remote inputNo-voltage input (with contacts, without contacts)
External outputOK/NG/FAIL/MEAS.Relay outputRated load 24 VDC 0.5AON resistance 50 m? or less
InterfaceLANRJ-45 (10BASE-T / 100BASE-TX / 1000BASE-T)
USB 2.0 series A6 ports (front: 2, rear: 4)
RecordHard disk drive250 GB
Illumination systemTransparentTelecentric transparent illumination (Green LED)
RingFour division ring illumination (White LED)
ExternalExternally connected illumination (coaxial)
X stageMoving range100 mm (electric)
Withstand load2 kg
Z stageMoving range30 mm (electric)
Power supplyPower voltage100 to 240 VAC 50 / 60 Hz
Power consumption310 mA or less
Environmental resistanceAmbient temperature+10 to +35 °C
Relative humidity20 to 80 % RH (No condensation)
WeightApprox 31 kg
*1 In the range of o80 mm from the centre of the stage within the operating temperature range of +23°C ±1°C at the focused focal point position *2 In the range of o20 mm from the centre of the stage within the operating temperature range of +23°C ±1°C at the focused focal point position *3 In the range of o80 ? 180 mm from the centre of the stage, within the operating temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 1 kg or less on the stage (L = amount of stage movement in mm units) *4 In the range of o20 ? 120 mm from the centre of the stage, within the operating temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 1 kg or less on the stage (L = amount of stage movement in mm units)