Датчик процесса Keyence FD-XS1E

В продаже Датчики процесса Датчик процесса Keyence FD-XS1E оптом и в розницу. Нашли дешевле? Предоставьте свою цену, Мы сформируем более выгодное предложение. При заказе от 3000р., доставка по Самаре - БЕСПЛАТНО! Возможна отправка товара в любую точку РФ транспортной компанией.

КУПИТЬ В 1 КЛИК
Цена:
Датчик процесса Keyence FD-XS1E

Технические характеристики

Характеристики - Датчик процесса Keyence FD-XS1E

Sensor head Maximum rated flow rate 1 L/min
ModelFD-XS1E
Supported pipe materialsMetal pipes, Plastic pipes (soft/hard) *1
Supported fluidsLiquids (water, oil, adhesive, grease, chemical solution, etc.) *1
Supported fluid temperature0 °C (no freezing on the pipe surface) to 100 °C (Pipe surface temperature)
Clamp set modelPlastic pipe/tube attachmentFD-XC1R1, FD-XC1R2
Metal pipe attachmentFD-XC1M
Maximum rated flow rate1000 mL/min
Zero cut flow rate50 mL/min*2 (variable, default)
Display resolutionInstantaneous flow rate1/10 mL/min (Displayed on controller)
RepeatabilityResponse time 50 ms: ±20 % of RD Response time 500 ms: ±15 % of RD
HysteresisVariable
Display methodStatus indicator
Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529) , IP68G (JIS C0920) *3
Operating ambient temperature0 to 60 °C (No freezing)
Operating ambient humidity35 % to 85 %RH (No condensation)
Vibration resistance10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X,Y,Z direction
Shock resistance50 G 11 ms, 3 times each for X,Y,Z direction
MaterialSensor headHead body: PPS/PPSU, relay amplifier: PPS, cable:PVC, controller connector: PPS/PBT/POM
Clamp setFor plastic pipeBody, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7
For metal pipeMetal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7
WeightApprox. 230 g
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe. *2 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate. *3 The connector part of the sensor head cable is IP65/IP67.