Датчик процесса Keyence FD-XA2

В продаже Датчики процесса Датчик процесса Keyence FD-XA2 оптом и в розницу. Нашли дешевле? Предоставьте свою цену, Мы сформируем более выгодное предложение. При заказе от 3000р., доставка по Самаре - БЕСПЛАТНО! Возможна отправка товара в любую точку РФ транспортной компанией.

КУПИТЬ В 1 КЛИК
Цена:
Датчик процесса Keyence FD-XA2

Технические характеристики

Характеристики - Датчик процесса Keyence FD-XA2

Controller DIN rail type, expansion unit
ModelFD-XA2
TypeDIN rail type, expansion unit
Display methodOutput indicator, 4-digit 7 segment display, OLED, Stability level display
Display refresh frequencyInstantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second
Response time50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms)
Integration data storage intervalWritten to the memory every 10 seconds
Memory back upEEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more)*1
Detection modech.1Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable)
ch.2Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable)
Input/outputOutputNPN/PNP setting switch Open collector output: 30 V or lower, main unit: 50 mA or lower/ch.*2/expansion unit: 20 mA or lower/ch., residual voltage: 2 V or lower
Analogue output-
External inputFlow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable) Short circuit current: NPN 1 mA or lower/PNP 2 mA or lower, input time: 20 ms or longer
Network supportSupports NU series
Protection circuitPower supply reverse connection protection, power surge protection, output short circuit protection, output surge protection
Addition of expansion unitsUp to 7*3 per main unit
Power supplyPower voltage20 to 30 VDC including 10 % ripple (P-P) , Class 2
Current consumption185 mA or lower (including the sensor head, excluding the load current)
Environmental resistanceOperating ambient temperature-10 to +50 °C (No freezing)
Operating ambient humidity35 % to 85 %RH (No condensation)
Vibration resistance10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X,Y,Z direction
Shock resistance100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction
MaterialMain body case/front sheet: PC, Key top: POM, Cable: PVC
WeightApprox. 180 g
*1 Internal data for full time recording can be read by USB (Ver.2.0) communication. *2 20 mA or lower/ch when adding expansion units. *3 Consult the manual for the number of serially-connectable devices to the N-bus.