Sensor Head, Small Spot
ModelLK-501
TypeSensor head
Measurement modeHigh-precision mode,Long-range mode
Reference distance350 mm (High-precision mode),500 mm (Long-range mode)
Measuring range±100 mm (High-precision mode),±250 mm (Long-range mode)
Light sourceTypeVisible red semiconductor laser
Wavelength690 nm
Output15mW
Laser ClassFDA (CDRH) 21CFR Part 1040.10Class 3B Laser Product
Laser ClassIEC 60825-1
Spot diameter (at standard distance)Approx. 0.7 mm (High-precision mode),Approx. 0.3 mm (Long-range mode)
Linearity±0.1% of F.S. *1
Repeatability10 µm*2 (High-precision mode), 50 µm*2 (Long-range mode)
Analogue outputOutput voltage±10 V (10 µm/mV)*3 (High-precision mode), ±5 V (50 µm/mV)*3 (Long-range mode)
Impedance100 ?
Output current4 to 20 mA (Applicable load: 350 ? max.)
Alarm outputNPN: 100 mA max. (40 V max.) (N.C.), Residual voltage: 1 V max.
Sampling cycle1,024 µs
Other functionsAuto-zero, analog output holding when an alarm occurs, gain switching, response switching, span and shift adjustment of mirror surface measurement mode, changing the sampling cycle
Temperature characteristics0.02% of F.S./°C
RatingPower voltage24 VDC ±10 %, Ripple (P-P) 10 % or less
Maximum current consumption400 mA max.
Environmental resistanceEnclosure ratingIP67
Ambient lightIncandescent or fl uorescent lamp: 10,000 lux max.
Ambient temperature0 to +50 °C (No condensation)
Relative humidity35 to 85 % RH (No condensation)
Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
MaterialAluminium die-cast
WeightApprox. 700 g (including cable)
*1 Linearity was obtained using KEYENCE's standard target (Zirconia block gauge: LK-031/036, LK-081/086, LK-011, White ceramic block gauge: LK-501/503). *2 Repeatability was obtained using KEYENCE's analogue sensor controller (RD-50) with the number of averaging measurements set to 64. Note: The ripple of the analogue output may be 1 mV or more due to co mmon mode noise when observed with an oscilloscope or a high-speed A/D conversion board. *3 When measurement is impossible, 12 V (31.2 mA) is output.