Датчик измерения Keyence LK-500

В продаже Датчики измерения Датчик измерения Keyence LK-500 оптом и в розницу. Нашли дешевле? Предоставьте свою цену, Мы сформируем более выгодное предложение. При заказе от 3000р., доставка по Самаре - БЕСПЛАТНО! Возможна отправка товара в любую точку РФ транспортной компанией.

КУПИТЬ В 1 КЛИК
Цена:
Датчик измерения Keyence LK-500

Технические характеристики

Характеристики - Датчик измерения Keyence LK-500

Sensor Head, Small Spot
ModelLK-500
TypeSensor head
Measurement modeHigh-precision mode,Long-range mode
Reference distance350 mm (High-precision mode),500 mm (Long-range mode)
Measuring range±100 mm (High-precision mode),±250 mm (Long-range mode)
Light sourceTypeRed semiconductor laser
Wavelength690 nm (visible light), JIS Class 3B*1
Output15 mW maximum
Spot diameter (at standard distance)Approx. 0.7 mm (high-precision mode), approx. 0.3 mm (long mode)
Linearity±0.1% of F.S.
Repeatability10 µm*2 (High-precision mode), 50 µm*2 (Long-range mode)
Analogue outputOutput voltage±10 V (10 µm/mV)*3 (High-precision mode), ±5 V (50 µm/mV)*3 (Long-range mode)
Impedance100 ?
Output current4 to 20 mA (350 ? maximum)*4*5
Alarm outputNPN: 100 mA max. (40 V max.) (N.C.), Residual voltage: 1 V max.
Sampling cycle1,024 µs
Other functionsAuto-zero, analog output holding when an alarm occurs, gain switching, response switching, span and shift adjustment
Temperature characteristics0.02% of F.S./°C
RatingPower voltage24 VDC ±10 %, Ripple (P-P) 10 % or less
Maximum current consumption400 mA max.
Environmental resistanceEnclosure ratingIP67
Ambient lightIncandescent or fl uorescent lamp: 10,000 lux max.
Ambient temperature0 to +50 °C (No condensation)
Relative humidity35 to 85 % RH (No condensation)
Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
MaterialAluminium die-cast
WeightApprox. 700 g (including cable)
*1 Contact KEYENCE for information on the type with a Class 2 laser. *2 Repeatability was obtained using KEYENCE's analogue sensor controller (RD-50) with the number of averaging measurements set to 64. Note: The ripple of the analogue output may be 1 mV or more due to co mmon mode noise when observed with an oscilloscope or a high-speed A/D conversion board. *3 When measurement is impossible, 12 V (31.2 mA) is output. *4 LK-010: When measurements cannot be performed, this is 12 V (21 mA). LK-035/030, LK-085/080, and LK-500: When measurements cannot be performed, this is 12 V (31.2 mA). *5 The ±5 V analog voltage output range (the ±