Датчик измерения Keyence IX-1050

В продаже Датчики измерения Датчик измерения Keyence IX-1050 оптом и в розницу. Нашли дешевле? Предоставьте свою цену, Мы сформируем более выгодное предложение. При заказе от 3000р., доставка по Самаре - БЕСПЛАТНО! Возможна отправка товара в любую точку РФ транспортной компанией.

КУПИТЬ В 1 КЛИК
Цена:
Датчик измерения Keyence IX-1050

Технические характеристики

Характеристики - Датчик измерения Keyence IX-1050

Sensor Amplifier Unite d’extension
ModelIX-1050
Main unit / expansion unitExpansion unit
DisplayMin. display unit10 µm*1
Display range±999.99 to ±999 mm (with 4 selectable steps)*1
ToolsScan modeHeight, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2
Line modeHeight (Ave./Max./Min.), Height difference (Ave./Max./Min.), Height difference calculation, Thickness calculation, Position adjustment, Tilt correction (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2
Other functionsCommonZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgement conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security
Scan modeMeasurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range
Line modeAverage count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)
InputNon-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
InputNumber of inputs8 (IN1 to IN8)
FunctionIN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgement value only) Reset (judgement value and error)
OutputOpen collector output, NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less
OutputNumber of outputs10 (OUT1 to OUT10)
FunctionEnable by assigning the optional functions Assignable functions: Total judgement result (All OK, Any OK/NG), run, busy, error, position adjustment result, tilt correction result, Monochromatic detection / Height detection tool result (OK/NG), Height / height difference / Max./Min. / calculation tool result (OK/NG/HIGH/LO), Alarm
Analogue voltage outputNot available
Analogue current output
Number of programs32
Statistical informationScan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1*3
Detection historySaved history100*4
Save conditionsSelectable from NG only / All*4
EthernetStandardNot available
Connector
Interface compatibilityCC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT? / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*5
Number of connectible unitsMain units: 1, Expansion units: 1, Communication units (DL): 1
RatingsPower voltageSupplied from main unit
Current consumptionMax. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *6
Environmental resistanceOperating ambient temperature0 to +50°C (No freezing)
Operating ambient humidity35 to 85% RH (No condensation)
MaterialMain unit case: PC / Power connector: PA, POM / Analogue output connector: PA, POM / I/O connector: PA / Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating / Rear heat sink: Aluminium / Main unit rear DIN rail fixing tab: POM / Nameplate: PC
WeightApprox. 190 g
*1 For displaying on an IX Series control panel or PC software. *2 Configurable for each program. *3 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set. *4 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software. *5 When a DL Series device is used. Contact KEYENCE for information on other interfaces. *6 Includes a DL Series communication unit.