Главная » Hengstler tico 732 Time counter
Hengstler tico 732 Time counter
В продаже Счетчики времени Hengstler tico 732 Time counter оптом и в розницу. Нашли дешевле? Предоставьте свою цену, Мы сформируем более выгодное предложение. При заказе от 3000р., доставка по Самаре - БЕСПЛАТНО! Возможна отправка товара в любую точку РФ транспортной компанией.
Технические характеристики
Характеристики - Hengstler tico 732 Time counter
The Tico 732 stands out as a result of its versatility and its multifunctional ability as a counter with up to two presets, as a tachometer, timer, shift or batch counter. The voltage supply is either 12 to 24 volts DC, 24 volts AC, 115 volts AC or 230 volts AC. The 6-digit display is noticeably easy to read and is available as either an LCD or an LED display. The device offers many programming options, has an integrated totalizing counter and is equipped with a keypad locking function. tico 732 Time counter
- Very easy operation
- LED or LCD display
- Up to two presets
| Product Family | tico 732 |
| Function | Time counter |
| Technology | Electronic |
| Digits | 6-digit |
| Display | - 6-digit
- count reading / preset
- leading zero suppression
- decimal point
|
| Preset | - 1 preset
- 2 presets
- without presets
|
| Digit Height [mm] | - LCD 9 mm (0.4 in)
- LED 7.6 mm (0.3 in)
|
| Display Variant | |
| Voltage | |
| Reset | - manual reset
- electrical reset
|
| Signal Times | 0.02 s to 1 s or bistable |
| Current Consumption [mA] | - 12-24 VDC, LCD: <100 mA
- 12-24 VDC, LED: 150 mA
- 24 VAC: <250 mA
- 100 VAC: < 60 mA
- 115 VAC: <50 mA
- 230 VAC: <25 mA each, incl. power to sensor
|
| Input Resistance | approx. 10 k? (static) |
| Pulse Length min. | - 17 ms (30 Hz)
- 100 ?s (5 kHz)
|
| Supply Voltage | - 12-24 VDC
- 24, 100, 115, 230 VAC
|
| Count Frequency [Hz] | max. 5 kHz (2,5 kHz using 2 channels) |
| Sensor Supply | |
| Storage of Values | NVM> 10 years |
| Electrical Connection | screw terminals |
| Amplitude Threshold | - 8 V or < 2 V and
- > 3.8 V at TTL levels
- max. 40 VDC
|
| Active Edge | programmable, positive with PNP input, negative with NPN input |
| Pulse Shape | any square wave (1:1 for max. frequency) |
| Prescaler | from 0.001 to 999.999 programmable |
| Relay (Preset 1 and 2) | - Varistor max. 250 VAC / 30 VDC
- min. 5 V AC/DC
- max. 5A
- min. 10 mA
- delay < 10 ms
|
| Transistor output (Preset 1 + 2) | - DC supply: PNP
- active high
- VDC-2V (supply voltage-2 V)
- max. 30 mA
- transformer version:PNP
- active high
- 12-30 VDC
- max. 30 mA
|
| Measuring Principle (tachometer) | period measurement (1/tau) |
| Display Range | 1/min or 1/sec |
| min. Frequency | 0.125 Hz = 8 sec |
| Limit Values | 2 alarms with programmable start suppression |
| Product Family | tico 732 |
| Function | Time counter |
| Technology | Electronic |
| Digits | 6-digit |
| Display | - 6-digit
- count reading / preset
- leading zero suppression
- decimal point
|
| Preset | - 1 preset
- 2 presets
- without presets
|
| Digit Height [mm] | - LCD 9 mm (0.4 in)
- LED 7.6 mm (0.3 in)
|
| Display Variant | |
| Voltage | |
| Reset | - manual reset
- electrical reset
|
| Signal Times | 0.02 s to 1 s or bistable |
| Current Consumption [mA] | - 12-24 VDC, LCD: <100 mA
- 12-24 VDC, LED: 150 mA
- 24 VAC: <250 mA
- 100 VAC: < 60 mA
- 115 VAC: <50 mA
- 230 VAC: <25 mA each, incl. power to sensor
|
| Input Resistance | approx. 10 k? (static) |
| Pulse Length min. | - 17 ms (30 Hz)
- 100 ?s (5 kHz)
|
| Supply Voltage | - 12-24 VDC
- 24, 100, 115, 230 VAC
|
| Count Frequency [Hz] | max. 5 kHz (2,5 kHz using 2 channels) |
| Sensor Supply | |
| Storage of Values | NVM> 10 years |
| Electrical Connection | screw terminals |
| Amplitude Threshold | - 8 V or < 2 V and
- > 3.8 V at TTL levels
- max. 40 VDC
|
| Active Edge | programmable, positive with PNP input, negative with NPN input |
| Pulse Shape | any square wave (1:1 for max. frequency) |
| Prescaler | from 0.001 to 999.999 programmable |
| Relay (Preset 1 and 2) | - Varistor max. 250 VAC / 30 VDC
- min. 5 V AC/DC
- max. 5A
- min. 10 mA
- delay < 10 ms
|
| Transistor output (Preset 1 + 2) | - DC supply: PNP
- active high
- VDC-2V (supply voltage-2 V)
- max. 30 mA
- transformer version:PNP
- active high
- 12-30 VDC
- max. 30 mA
|
| Measuring Principle (tachometer) | period measurement (1/tau) |
| Display Range | 1/min or 1/sec |
| min. Frequency | 0.125 Hz = 8 sec |
| Limit Values | 2 alarms with programmable start suppression |